Chinook APU engine info

Thread Tools
 
Search this Thread
 
Old 14th Mar 2012, 20:36
  #1 (permalink)  
gub
Thread Starter
 
Join Date: Mar 2012
Location: bewdley
Posts: 11
Likes: 0
Received 0 Likes on 0 Posts
memory loss

It has taken 137 attempts to re-register on PPrune. This is due to a failing memory, dyslexia and numerous other issues pertaining to old age. In a moment of complete insanity I have just purchased a little helicopter powered by a ...doh...solar t62 - 2a gas turbine (phew...that took some doing) and really need someone that has technical info on such a device. Here's hoping! Thanks, Gub. Formally known as 'bug' in a former life, prior to the divorce from a lady half his age and a loss of £100,000 - was it worth it? NO!
gub is offline  
Old 15th Mar 2012, 21:58
  #2 (permalink)  
gub
Thread Starter
 
Join Date: Mar 2012
Location: bewdley
Posts: 11
Likes: 0
Received 0 Likes on 0 Posts
Chinook APU engine info

Is there anyone on here with information about the apu on the chinoux
gub is offline  
Old 15th Mar 2012, 23:03
  #3 (permalink)  
 
Join Date: Jul 2010
Location: Shelton WA.
Posts: 339
Likes: 0
Received 1 Like on 1 Post
Auxiliary Power Unit (APU). - Boeing H-47 Chinook helicopter



www.chinook-helicopter.com/standards/areas/apu.html



Could start here.
Gemini Twin is offline  
Old 15th Mar 2012, 23:41
  #4 (permalink)  
 
Join Date: Dec 2007
Location: GMT
Age: 53
Posts: 2,105
Received 205 Likes on 80 Posts
1. Pain in the ass to pump up.
2. Works off pressure from APU start accumulator 3000psi, though the engineers will tell you '2-2 starts the poo'.
3. Sometimes the start module solenoid 'sticks' and needs gentle caressing with something heavy.
4. Noisy.
5. Once started produces 3350psi (the extra being for the engine start).
6. See 1.
minigundiplomat is offline  
Old 16th Mar 2012, 21:28
  #5 (permalink)  
gub
Thread Starter
 
Join Date: Mar 2012
Location: bewdley
Posts: 11
Likes: 0
Received 0 Likes on 0 Posts
Chinook apu

Many thanks for the info!.. I was told this apu was used in the chinook but the particular model i have is a t62t-2a1, the turbine looks identical to the one on the website you gave me but the reduction box on mine is different. I am told there is a temperature sensor mounted if the exhaust outlet to shut down the turbine if it exceeds a certain temperature. has anyone any idea if this is correct and if so what temperature range is acceptable. Thanks gub.
gub is offline  
Old 17th Mar 2012, 01:39
  #6 (permalink)  
 
Join Date: May 2002
Location: Downeast
Age: 75
Posts: 18,315
Received 585 Likes on 242 Posts
We used to carry a bit of stiff wire as a jumper for part of the APU start circuits....when they decided not to start for an over temp signal....that and a big Witch's broom for fending off a tail wind from the exhaust which would also trick the thing into not starting.

Yes....pumping said accumulator by hand....much fun!
SASless is offline  
Old 17th Mar 2012, 06:02
  #7 (permalink)  
 
Join Date: Dec 2006
Location: Here and there...
Age: 58
Posts: 854
Likes: 0
Received 0 Likes on 0 Posts
Try this, don't know if it's your version, though...

Download: Solar t62t 2a1 at Marks Web of Books and Manuals
unstable load is offline  
Old 17th Mar 2012, 21:14
  #8 (permalink)  
 
Join Date: Oct 2005
Location: Anglia
Posts: 2,077
Received 16 Likes on 6 Posts
The APU shuts down when the EGT exceeds 577-588 Deg C.
(found my Chinny notes!)
Rigga is offline  
Old 17th Mar 2012, 22:38
  #9 (permalink)  
gub
Thread Starter
 
Join Date: Mar 2012
Location: bewdley
Posts: 11
Likes: 0
Received 0 Likes on 0 Posts
chinook apu

Many thanks for all the info gentlemen, very informative will post piccies when i have it buzzing, Gub.
gub is offline  
Old 18th Mar 2012, 18:43
  #10 (permalink)  
 
Join Date: Sep 2007
Location: On the Rump of Pendle Hill Lancashi
Posts: 614
Likes: 0
Received 0 Likes on 0 Posts
Gub,

Commiserations on the loss of a younger Filly, but I would say £100K is a good price to get rid of an obvious problem, remeber one thing though

1. DONT DO IT AGAIN.....or if ya do cos we are all human...keep your purse closed, I say purse cos all us Oldies have one

2. IF YOU DO< DO IT AGIN...do it for fun dont get all soppy

3. Oh and change your will!

Peter Rb
Lancashire
Peter-RB is offline  
Old 18th Mar 2012, 20:00
  #11 (permalink)  
 
Join Date: Jun 2002
Location: east ESSEX
Posts: 4,699
Received 75 Likes on 48 Posts
Don`t `buy`....just rent.....!
sycamore is offline  

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are Off
Pingbacks are Off
Refbacks are Off



Contact Us - Archive - Advertising - Cookie Policy - Privacy Statement - Terms of Service

Copyright © 2024 MH Sub I, LLC dba Internet Brands. All rights reserved. Use of this site indicates your consent to the Terms of Use.